Every signal. The right edge device.

DelphEon edge devices bring legacy machines, analog sensors, electrical loads and remote assets into the DelphEon Industrial OS, through I/O and sensor modules, a field telemetry unit and long-range wireless.

The device range

Four devices. One connected platform.

Each device solves a different connection problem on the plant floor. Together they cover legacy equipment, field signals, electrical loads and remote sites.

DelphEon FTU field transmission unit

Field telemetry unit

DelphEon FTU

A field transmission unit for remote assets. It logs, processes and transmits sensor data to central systems, even in challenging environments.

  • Wide I/O 20 analog and 4 digital I/O for comprehensive asset monitoring.
  • Switchable analog inputs Choose 4–20 mA or 0–10 V to suit each sensor.
  • Modular backplane Add analog or digital inputs with I/O daughter cards.
  • Local processing ARM Cortex-A53 for data logging and edge processing.
  • ARM Cortex-A53
  • 20 analog · 4 digital I/O
  • 4–20 mA / 0–10 V
  • Modbus TCP
  • Expandable I/O cards
DelphEon I/O Module with analog input, relay output, Ethernet and power terminals

I/O & protocol converter

DelphEon I/O Module

Brings legacy equipment into remote monitoring and control. Analog inputs, digital I/O and relay outputs connect directly to sensors and actuators.

  • Protocol conversion Bridges Modbus TCP (Ethernet) and Modbus RTU (RS-485) devices.
  • Web-based setup Built-in HTTP web server for configuration and status.
  • Flexible power Power over Ethernet (PoE) or a 24 V DC supply.
  • Robust I/O Optically isolated inputs and outputs for industrial sites.
  • Analog inputs
  • Digital I/O
  • Relay outputs
  • Modbus TCP/RTU
  • PoE or 24 V DC
  • Optically isolated
Two DelphEon RF Connect wireless units with antennas

Long-range wireless

DelphEon RF Connect

Long-range wireless transmission from remote locations to a central site. It uses the license-free RF band in India, so no complex field wiring is needed.

  • Long range Several kilometres in line of sight.
  • Self-healing mesh Keeps data moving in environments with interference.
  • No field wiring Compact and cost-effective to install.
  • Standards based IEEE 802.15.4g/e with Modbus RTU.
  • License-free RF band (India)
  • IEEE 802.15.4g/e
  • Modbus RTU
  • Self-healing mesh
  • Several km line of sight
Three DelphEon Sensor Connect modules for current and voltage measurement

Current & voltage sensing

Sensor Connect Module

Precise contactless current and voltage measurement for industrial loads. Advanced isolation keeps equipment safe while the modular design saves panel space.

  • Precise and safe Accurate measurement with advanced isolation.
  • Compact and modular Stackable and DIN-rail mountable.
  • Less wiring Daisy-chain power supply between modules.
  • Rugged Built for harsh environments, with surge protection.
  • Contactless current
  • Voltage
  • Advanced isolation
  • DIN rail, stackable
  • Daisy-chain power
  • Surge protection

Selection guide

Start from the signal, not the catalogue.

Compare at a glance

DeviceRoleI/O & interfacesProtocolsDesign & power
DelphEon FTUField telemetry unit20 analog and 4 digital I/O, 4–20 mA or 0–10 V, expandable with I/O daughter cardsModbus TCPModular backplane architecture
DelphEon I/O ModuleI/O & protocol converterAnalog inputs, digital I/O, relay outputs; Ethernet and RS-485Modbus TCP/RTU, with conversion between themOptically isolated I/O; PoE or 24 V DC
DelphEon RF ConnectLong-range wirelessWireless link over the license-free RF band (India), several km line of sightIEEE 802.15.4g/e, Modbus RTUCompact; self-healing mesh; no field wiring
Sensor Connect ModuleCurrent & voltage sensingContactless current and voltage measurementConfirm for your modelStackable, DIN rail, daisy-chain power, surge protection

Specifications summarise the published catalogue. Confirm the current model, firmware, available interfaces, installation requirements and supply scope with our team before selection. A listed protocol does not guarantee access to every machine signal.

From signal list to rollout

A practical path to the right hardware

  1. Share your signal list

    Controller models, firmware and options, the signals you need, a network diagram and sample data.

  2. Assess access

    We check which signals each source exposes and match the right device and protocol to it.

  3. Prove it on one asset

    Start with a representative legacy and modern asset, and verify the signal map and recovery.

  4. Scale with confidence

    Roll out to more machines and sites using reusable configurations.

Questions

Edge hardware, answered

Can’t find your question? Ask our team

Do I need DelphEon hardware to use the platform?

Not always. Existing industrial systems can be integrated, and we confirm the right approach for each project.

Which device should I start with?

Start from the signal. For many analog signals on a remote asset, use the FTU. To add I/O to a legacy machine, use the I/O Module. Where cabling is impractical, use RF Connect. To measure electrical loads, use the Sensor Connect Module.

Can the devices work where there is no network cabling?

Yes. DelphEon RF Connect provides long-range wireless links over several kilometres in line of sight.

Does a listed protocol guarantee access to every machine signal?

No. Signal access depends on the controller model, options and firmware. We assess the exact source and device version before selection.

Find the right hardware for your plant.

Tell us which machines, sensors and sites you need to connect. Our team will recommend a practical device and connectivity approach.

Discuss Your Hardware Requirements